dc.description.abstract | Bu tez çalışmasında, gelişen radyoterapi tekniklerinden yoğunluk ayarlı radyoterapi, hacimsel yoğunluk ayarlı radyoterapi, stereotaktik radyocerrahi gibi gelişmiş tedavi tekniklerinde kullanılan 6 MV foton demetinin küçük alan boyutlarındaki dozimetrik verileri (yüzde derin doz, profil, rölatif doz faktörleri) farklı dedektörler ile ölçülmüştür. Bu verilerin Monte Carlo (MC) kodları kullanılarak oluşturulan simülasyon verileriyle karşılaştırılması hedeflenmiştir. Çalışmada, referans dedektörün ölçümdeki etkisi araştırılmış; farklı dedektörler referans dedektör olarak kullanılarak 1x1 ve 5x5 cm² alanlarda yüzde derin doz ve profil eğrileri elde edilmiştir. Farklı dedektörlerin, farklı konumlarda referans dedektör olarak kullanılması ile elde edilen dozimetrik veriler değerlendirilmiş ve referans dedektörün tipi ve konumu belirlenmiştir. Çalışmada, 10x10, 5x5, 4x4, 3x3, 2x2 ve 1x1 cm² alan boyutları için farklı hacimlere ve özelliklere sahip Semiflex, Pinpoint iyon odaları ve Edge, diyotSRS, microDiamond dedektörler kullanılarak su fantomunda yüzde derin doz ölçümleri gerçekleştirilmiştir. Farklı ölçüm düzenekleri ile beş farklı dedektör kullanılarak dmaks (1.5cm), 5 ve 10 cm derinliklerde X ve Y-yönü profilleri alınmıştır. Rölatif doz faktörü (RDF) ölçümleri üç değişik dedektör (Semiflex, Pinpoint, Edge) ile yapılmış ve bulunan değerler MC ile bulunan değerlerle karşılaştırılmıştır. Ölçümler önceki gibi farklı dedektörler kullanılarak 10x10, 5x5, 4x4, 3x3, 2x2 ve 1x1 cm² alan boyutlarında gerçekleştirilmiştir. Sonuç olarak, bu çalışmada 6 MV foton demeti için küçük alan boyutlarındaki dozimetrik verilerin farklı dedektörler kullanılarak ölçülmesi ve bu verilerin Monte Carlo simülasyonu ile karşılaştırılması amaçlanmıştır. Bu çalışma, tedavi cihazlarının dozimetrik verilerinin doğru bir şekilde tedavi planlama sistemine tanıtılması ve radyoterapi hastalarının tedavisinde kullanılan dozimetrik verilerin doğruluğunun sağlanmasında önemlidir. | en_US |
dc.description.abstract | In this thesis study, dosimetric data of a 6 MV photon beam with small field sizes used in advanced treatment techniques such as intensity-modulated radiotherapy, volumetric-modulated arc therapy, stereotactic radiosurgery, etc., were measured with different detectors. The aim was to compare these data with simulation data generated using Monte Carlo (MC) codes. The study investigated the effect of the reference detector on measurements. Different detectors were used as the reference detector to
obtain percent depth dose and profile curves for 1x1 and 5x5 cm² fields. The dosimetric data obtained by using different detectors as the reference detector at different positions were evaluated, and the type and position of the reference detector were determined. For different field sizes of 10x10, 5x5, 4x4, 3x3, 2x2, and 1x1 cm², percent depth dose measurements were performed in a water phantom using Semiflex, Pinpoint ion chambers, and Edge, diodeSRS, microDiamond detectors with different volumes and
characteristics. Five different detectors were used with different measurement setups to obtain X and Y-axis profiles at dmax (1.5 cm), 5 cm, and 10 cm depths. Relative dose factor (RDF) measurements were performed with three different detectors (Semiflex, Pinpoint, Edge), and the obtained values were compared with the values obtained from MC. Measurements were carried out with different detectors for 10x10, 5x5, 4x4, 3x3, 2x2, and 1x1 cm² field sizes, as before. In conclusion, the aim of this study was to
measure dosimetric data of small field sizes for a 6 MV photon beam using different detectors and compare these data with Monte Carlo simulation. This study is important for the accurate introduction of dosimetric data of treatment devices into the treatment planning system and ensuring the accuracy of dosimetric data used in the treatment of radiotherapy patients. | en_US |
dc.language.iso | tur | en_US |
dc.publisher | Balıkesir Üniversitesi Fen Bilimleri Enstitüsü | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Küçük Alan Dozimetrisi | en_US |
dc.subject | Monte Carlo Simülasyonu | en_US |
dc.subject | İyon Odası | en_US |
dc.subject | Small Field Dosimetry | en_US |
dc.subject | Monte Carlo Simulation | en_US |
dc.subject | İon Chamber | en_US |
dc.title | Küçük alan foton dozimetrisi ve Monte Carlo simülasyonu | en_US |
dc.title.alternative | Small field photon dosimetry and Monte Carlo simulation | en_US |