Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorSarıca, Meryem
dc.contributor.authorAydoğdu, Uğur
dc.date.accessioned2025-01-16T06:56:16Z
dc.date.available2025-01-16T06:56:16Z
dc.date.issued2024en_US
dc.identifier.issn0236-6290 / 1588-2705
dc.identifier.urihttps://doi.org/10.1556/004.2024.00951
dc.identifier.urihttps://hdl.handle.net/20.500.12462/15789
dc.descriptionAydoğdu, Uğur (Balikesir Author)en_US
dc.description.abstractIn this study, we aimed to determine the quality of colostrum in sheep by using Brix refractometer. The research included 100 sheep of Merino X Kivircik crossbred. From each, we collected 15 mL of colostrum samples in falcon tubes within the first 8 h after delivery. Mean colostral IgG level of sheep was 156.68 ± 7.23 g L-1, optical and digital Brix refractometer values (%) were determined as 27.43 ± 0.53 and 27.69 ± 0.60, respectively. Ewes carrying twin lambs produced significantly higher quality colostrum than those carrying single lambs. However, parity did not affect the colostrum quality. Optical and digital Brix values were correlated with gold standard radial immunodiffusion (RID) colostral IgG level (r = 0.70 and r = 0.64, respectively). Also, optical and digital Brix refractometers were found to be highly correlated (r = 0.98, P < 0.001). While the optimal Brix value was 22% for the 50, 60 and 70 g L-1 IgG threshold values (by means of RID as the potential good quality threshold value for ewe colostrum quality), this value was 23% for 80 g L-1. We can conclude that Brix refractometers is a valuable tool for determining ewe colostrum quality. A cut point of 22% Brix for defining good quality colostrum in ewes was most appropriate for our data.en_US
dc.description.sponsorshipBalikesir University Scientific Research Projects Coordinator 2020/087en_US
dc.language.isoengen_US
dc.publisherAkademiai Kiado ZRT.en_US
dc.relation.isversionof10.1556/004.2024.00951en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBrix Refractometeren_US
dc.subjectColostrumen_US
dc.subjectIgGen_US
dc.subjectRadial Immunodiffusionen_US
dc.subjectSheepen_US
dc.titleDetermination of colostrum quality using Brix refractometer in sheepen_US
dc.typearticleen_US
dc.relation.journalActa Veterinaria Hungaricaen_US
dc.contributor.departmentVeteriner Fakültesien_US
dc.contributor.authorID0000-0002-9828-9863en_US
dc.identifier.volume72en_US
dc.identifier.issue2en_US
dc.identifier.startpage116en_US
dc.identifier.endpage124en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster