Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorKara, Derya
dc.contributor.authorFisher, Andrew
dc.contributor.authorHill, Steve
dc.date.accessioned2019-10-17T07:04:56Z
dc.date.available2019-10-17T07:04:56Z
dc.date.issued2005en_US
dc.identifier.issn0003-2654
dc.identifier.issn1364-5528
dc.identifier.uri10.1039/b508841k
dc.identifier.urihttps://hdl.handle.net/20.500.12462/7462
dc.descriptionKara,Derya (Balikesir Author)en_US
dc.description.abstractAn on-line flow injection method for the direct determination of trace elements in environmental samples is described. A mini-column packed with 2,6-diacetylpyridine functionalized Amberlite XAD-4 was used to preconcentrate and separate 8 trace metals (Cd, Co, Cu, Mn, Ni, Pb, U and Zn) from water and extracts from solid samples. The metals were eluted with 0.1 M HNO3 directly to the detection system ( either inductively coupled plasma-mass spectrometry (ICP-MS) or flame atomic absorption spectrometry (FAAS)). As well as demonstrating that the resin could be used to preconcentrate ultra-trace analytes from natural waters, it was also shown to work well at a pH of 5.5. Therefore, after treatment of sample digests with sodium fluoride, samples that contain extremely large concentrations of iron may be analysed for trace analytes without the excess iron overloading the capacity of the resin. To this end, the analytes Cd, Co, Cu and Ni were preconcentrated from acid extracts of certified soil/sediment samples and then eluted with nitric acid to be determined on-line. Limits of detection (3 sigma) of Cd=0.33 mu g l(-1), Co=0.094 mu g l(-1), Cu=0.34 mu g l(-1), Mn=0.32 mu g l(-1), Ni=0.30 mu g l(-1), Pb=0.43 mu g l(-1), U=0.067 mu g l(-1) and Zn=0.20 mu g l(-1) for the FI-ICP-MS system and Cd=22 mu g l(-1), Co=60 mu g l(-1), Cu=10 mu g l(-1) and Ni=4.8 mu g l(-1) for the FI-FAAS system were obtained. Analysis of certified reference materials showed good agreement with the certified values using the two methods.en_US
dc.language.isoengen_US
dc.publisherRoyal Soc Chemistryen_US
dc.relation.isversionof10.1039/b508841ken_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAbsorption-Spectrometryen_US
dc.subjectEmission-Spectrometryen_US
dc.subjectSaline Matricesen_US
dc.subjectPolymer Matrixen_US
dc.subjectMetal-İonsen_US
dc.subjectSeparationen_US
dc.subjectZinc(II)en_US
dc.subjectWater Samplesen_US
dc.titlePreconcentration and determination of trace elements with 2,6-diacetylpyridine functionalized Amberlite XAD-4 by flow injection and atomic spectroscopyen_US
dc.typearticleen_US
dc.relation.journalAnalysten_US
dc.contributor.departmentFen Edebiyat Fakültesien_US
dc.contributor.authorID0000-0003-4373-4904en_US
dc.identifier.volume130en_US
dc.identifier.issue11en_US
dc.identifier.startpage1518en_US
dc.identifier.endpage1523en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster