Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorKaradaş, Cennet
dc.contributor.authorKara, Derya
dc.date.accessioned2019-10-17T08:14:26Z
dc.date.available2019-10-17T08:14:26Z
dc.date.issued2013en_US
dc.identifier.issn0889-1575
dc.identifier.issn1096-0481
dc.identifier.urihttps://doi.org/10.1016/j.jfca.2013.07.003
dc.identifier.urihttps://hdl.handle.net/20.500.12462/7911
dc.description.abstractA new chelating resin has been developed using Amberlite XAD-4 resin anchored with 8-hydroxy-2-quinoline carboxaldehyde through -C=N- group. The synthesized resin, characterized by infrared spectroscopy, was used as packing for the minicolumn in an on-line preconcentration system for cadmium, cobalt, copper, lead, manganese and nickel (Cd, Co Cu, Pb, Mn and Ni) determination. Metal ions retained on the modified resin were eluted using 1.0 mol L-1 HNO3 solution and aspirated directly to the nebulizer-burner system of a FAAS instrument using a flow injection system. Optimum hydrodynamic and chemical conditions for metal sorption were investigated. Detection limits (3 sigma-) were determined to be 0.14 mu g L-1 for Cd, 0.35 mu g L-1 for Cu, 0.26 mu g L-1 for Mn, 0.70 mu g L-1 for Co, 0.72 mu g L-1 for Ni and 2.92 mu g L-1 for Pb using a 10 mL sample loading. Enrichment factors for Cu(II), Mn(II), Co(II), Pb(II), Ni(II) and Cd(II) were found to be 22.3, 24.7, 23.2, 24.1, 20.2 and 27.6, respectively. The proposed method was successfully applied to the determination of analytes in water samples, and in food samples such as cereal certified reference materials.en_US
dc.description.sponsorshipBalikesir University - 2012/35en_US
dc.language.isoengen_US
dc.publisherAcademic Press Inc Elsevier Scienceen_US
dc.relation.isversionof10.1016/j.jfca.2013.07.003en_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectFlame Atomic Absorption Spectrometry (FAAS)en_US
dc.subjectOn-Line Preconcentrationen_US
dc.subjectLimit Of Detectionen_US
dc.subjectLODen_US
dc.subjectHeavy Metal Contamination In Fooden_US
dc.subjectFood Safetyen_US
dc.subjectMatrix Interference Effecten_US
dc.subjectAmberlite XAD-4en_US
dc.subject8-Hydroxy-2-Guinoline Carboxaldehydeen_US
dc.subjectTrace Elementsen_US
dc.subjectFood Analysisen_US
dc.subjectWater Analysisen_US
dc.subjectFood Compositionen_US
dc.titleOn-line preconcentration and determination of trace elements in waters and reference cereal materials by flow injection - FAAS using newly synthesized 8-hydroxy-2-quinoline carboxaldehyde functionalized Amberlite XAD-4en_US
dc.typearticleen_US
dc.relation.journalJournal Of Food Composition And Analysisen_US
dc.contributor.departmentFen Edebiyat Fakültesien_US
dc.contributor.authorID0000-0003-0 993-1488en_US
dc.identifier.volume32en_US
dc.identifier.issue1en_US
dc.identifier.startpage90en_US
dc.identifier.endpage98en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster