Pharmacomechanical thrombolysis with a rotator thrombolysis device in iliofemoral deep venous thrombosis
Access
info:eu-repo/semantics/closedAccessDate
2016Author
Karahan, OğuzKutas, H. Barış
Gürbüz, Orçun
Tezcan, Orhan
Çalışkan, Ahmet
Yavuz, Celal
Demirtaş, Sinan
Mavitaş, Binali
Metadata
Show full item recordAbstract
Objective Deep venous thrombosis (DVT) is a life-threatening and morbid pathology. This study aimed to investigate the efficacy of an early thrombolysis procedure using a rotator thrombolysis device.Methods Sixty-seven patients with acute proximal DVT were enrolled in the study. Patients' data were recorded retrospectively. Initially, an infrarenal retrievable vena cava filter was placed through the femoral vein. Then, a rotator thrombolysis device and a thrombolytic agent injection were applied to the occluded segments of the deep veins by puncturing the popliteal vein. Results The identified reasons were trauma (43.3%), pregnancy (20.9%), undiagnosed (11.9%), major surgical operation (10.5%), immobilization (7.5%), and malignancy (5.9%). Immediate total recanalization was conducted in all patients, and the leg diameters returned to normal ranges in the early postoperative period. Hospital mortality or severe complications were not detected.
Conclusion New thrombolytic devices seem to reduce in-hospital mortality risks and may potentially decrease post-thrombotic morbidity.