dc.description.abstractAim: Incorrect values of applanation tonometers according to varying corneal thickness were investigated many times. In this study, we aimed to compare intraocular pressure (IOP) measurements of the Tono-Pen and Goldman applanation tonometer (GAT) in eyes with normal corneas of various thicknesses. Material and Method: IOP was measured with Tono-Pen and GAT respectively in 255 patients' eyes with normal corneas. Only the right eyes were analyzed for statistical purposes. Central corneal thickness (CCT) was measured using an ultrasound pachymeter after all IOP determinations had been made. Results: With both instruments, IOP varied with CCT. Readings with Tono-Pen showed a mean increase in IOP with increasing CCT of 0,18 mmHg/10 mu m and an increase of 0,16 mmHg/10 mu m with the GAT. The Tono-Pen consistently recorded comparatively higher IOPs than the GAT (p < 0,05). Discussion: In our study, the difference between the Tono-Pen and GAT measurements is statistically insignificant and 60% of this difference is within the 1 mmHg range. Although it is thought that Tono-Pen may be less affected by corneal thickness due to the measurement from a smaller area we did not obtain data that Tono-Pen is less affected by corneal thickness as a result of linear regression analysis. The Tono-Pen is more affected by CCT when used to measure IOP in eyes with normal corneas. This is contrary to expectations, based on the theory that Tono-Pen is least affected by the CCT because it needs smaller applanation area.en_US
dc.language.isoengen_US
dc.publisherBayrakol Medical Publisheren_US
dc.relation.isversionof10.4328/ACAM.5996en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectTono-penen_US
dc.subjectGoldman Applanation Tonometeren_US
dc.subjectIntraocular Pressureen_US
dc.subjectCentral Corneal Thicknessen_US
dc.titleComparison of the intraocular pressure measurements with the tono-pen and the goldman applanation tonometer and the effect of central corneal thickness on measurementsen_US
dc.typearticleen_US
dc.relation.journalAnnals of Clinical and Analytical Medicineen_US
dc.contributor.departmentTıp Fakültesien_US
dc.contributor.authorID0000-0003-2006-2906en_US
dc.identifier.volume10en_US
dc.identifier.issue4en_US
dc.identifier.startpage479en_US
dc.identifier.endpage484en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster