dc.contributor.authorDervişoğulları, Mehmet Serdar
dc.contributor.authorAkarsu, Cengiz
dc.contributor.authorErgin, Ahmet
dc.date.accessioned2021-09-28T10:31:05Z
dc.date.available2021-09-28T10:31:05Z
dc.date.issued2020en_US
dc.identifier.issn1305-9173 / 2717-7157
dc.identifier.urihttps://doi.org/10.37844/glauc.cat.2020.15.6
dc.identifier.urihttps://hdl.handle.net/20.500.12462/11666
dc.descriptionErgin, Ahmet (Balikesir Author)en_US
dc.description.abstractPurpose: Incorrect values of applanation tonometers according to varying corneal thickness were investigated many times. In this study, we aimed to compare intraocular pressure (IOP) measurements of the Tono-Pen and Goldmann applanation tonometer (GAT) in eyes with normal corneas of various thicknesses. Material and Methods: IOP was measured with Tono-Pen and GAT respectively in 255 patients’ eyes with normal corneas. Only the right eyes were analyzed for statistical purposes. Central corneal thickness (CCT) was measured using an ultrasound pachymeter after all IOP determinations had been made. Results: With both instruments, IOP varied with CCT. Readings with Tono-Pen showed a mean increase in IOP with increasing CCT of 0,18 mmHg/10μm and an increase of 0,16 mmHg/10 μm with the GAT. The Tono-Pen consistently recorded comparatively higher IOPs than the GAT (p<0,05). Conclusion: In our study, the difference between the Tono-Pen and GAT measurements is statistically insignifi cant and 60% of this difference is within the 1 mmHg range. Although it is thought that Tono-Pen may be less affected by corneal thickness due to the measurement from a smaller area we did not obtain data that Tono-Pen is less affected by corneal thickness as a result of linear regression analysis.The Tono-Pen is more affected by CCT when used to measure IOP in eyes with normal corneas. This is contrary to expectations, based on the theory that TonoPen is least affected by the CCT because it needs smaller applanation area.en_US
dc.language.isoengen_US
dc.publisherGazi Göz Vakfıen_US
dc.relation.isversionof10.37844/glauc.cat.2020.15.6en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectTono-Penen_US
dc.subjectGoldmann Applanation Tonometeren_US
dc.subjectIntraocular Pressureen_US
dc.subjectCentral Corneal Thicknessen_US
dc.titleComparison of the intraocular pressure measurements with the tono-pen and the goldmann applanation tonometer and the effect of central corneal thickness on measurementsen_US
dc.typearticleen_US
dc.relation.journalGlokom Katarakten_US
dc.contributor.departmentTıp Fakültesien_US
dc.identifier.volume15en_US
dc.identifier.issue1en_US
dc.identifier.startpage27en_US
dc.identifier.endpage32en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster