dc.description.abstractCompartment syndrome (CS) is a threatening condition characterized by excessive tissue pressure accumulation associated with acute trauma. Compartment syndrome causes a significant reduction in blood flow with subsequent muscle and nerve ischemic necrosis. Recently, reports have described the importance of intramuscular pressure measurements as a basis for CS diagnosis. Unfortunately, the measuring devices that were utilized produced results with unsatisfactory reliability, making a diagnosis and subsequent treatment challenging. Here, we report the use of an anesthesia pressure monitoring device with greater precision for pressure measurements, as well as real-time monitoring of intraoperative compartment pressure decompression efficacy. This device enabled the accurate diagnosis and rapid treatment of a thenar compartment syndrome (TCS) in the left hand of a diabetic female in an emergency setting. She presented extreme pain in the thumb flexion-extension (FE). Her condition was complicated by diabetic cellulitis, primarily of Staphylococcus aureus. Consequently, successful microsurgery in the thenar space, together with debridement, resulted in remarkable pain relief during FE of the thumb metacarpophalangeal (MCP) and interphalangeal (IP) joints, as well as the disappearance of the infection by Day 10. Subsequent one- to two-year follow-up assessments revealed marked recovery.en_US
dc.language.isoengen_US
dc.publisherCureus Inc.en_US
dc.relation.isversionof10.7759/cureus.2197en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectPressure Monitoring Deviceen_US
dc.subjectThenar Compartment Syndromeen_US
dc.subjectCompartment Syndrome of The Handen_US
dc.subjectHand Injuryen_US
dc.subjectAnesthesia Machine Compartment Pressure Measurementen_US
dc.subjectMicrosurgeryen_US
dc.subjectCompartment Pressure Measurementen_US
dc.subjectPressure Monitorized Compartment Releaseen_US
dc.subjectCompartment Syndromeen_US
dc.subjectCompartment Pressureen_US
dc.titleThenar compartment syndrome: what if a compartment pressure measuring device is absent?en_US
dc.typearticleen_US
dc.relation.journalCureusen_US
dc.contributor.departmentTıp Fakültesien_US
dc.identifier.volume10en_US
dc.identifier.issue2en_US
dc.identifier.startpage1en_US
dc.identifier.endpage8en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster